Home > Buy Now > Generators > Other Generators > Series T 24KW-1000KW Natural Gas Generator
 


Qingdao Fortune Import & Export Co., Ltd
 
icon Products

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Qingdao Fortune Import & Export Co., Ltd
[China]
Address:
Tower A, Yinxi Park, #42 Shandong Road Qingdao Shandong 266071 China
Phone:
86-0532-86122828
Contact name:
Su James
Inquire now










Qingdao Fortune Import & Export Co., Ltd



 
Products

Series T 24KW-1000KW Natural Gas Generator

Inquire now

Series T 24KW-1000KW Natural Gas Generator

Click to enlarge image

 Model Number FNGF24T-1000T

“Fortune” series gas generator takes an ignitable gas as the fuel, such as natural gas, liquefied petroleum gas, well associated gas, methane gas and so on, using the advanced technology such as closed-loop control, digital ignition, electrically controlled gas supply and electronic speed regulating, is an  ideal power for petroleum recovering, water flooding pump, collection pump station as well as small power plant.
  ”Fortune” series gas power generator can be equipped with synchronization brushless engines made in accordance with importing permit certificate, also in accordance with user’s appointment. The power generator has a good control system, adopting high grade series monitoring devices, having protective functions for less voltage, over current, automatic adjusting voltage, reverse power, simultaneously monitoring running parameters of the generators, such as rotational speed, water temperature, oil temperature, exhaust temperature, and also equipped with the overstep optic alarm and auto-stop function.

Advantages of gas generator
1
: Energy direct supply
  Unnecessary to store up massive dangerous materials (fuel), may directly supply fuel gas by public pipeline, with features of safety, convenience.
2
: Clean and environment friendly
  Gas generator’s harmful discharging is low, basically without pollution to the air, being extremely environment friendly
3: Long lifespan
  In case of correct use and maintenance, the gas engines can be used for many years.
4: Low running cost
  The natural gas resource is rich, with inexpensive price and quick investment repaying back.
5: Low cost high benefit
  The operating cost is low, may simultaneously supply electric power and thermal energy, with low maintenance cost.

Model of Gen-set

24GF-RT

engine model

T1190

generator model

CW-24

rated power (kW)

24

rated current A

43.3

rated voltageV

400/230

rated power factorCOSΦ

0.8lag

frequencyHz

50

start-up method

DC 24V

voltage regulation

automatic

Exciting method

brushless

Connecting Method

3 phase-4 wire connection

drive method of generator

belt  pulling

Cylinder bore (mm)

190

compression ratio

9:01

rated speed  (r/min)

850

lube oil consumption ratio

1.5g/kWh

overall dimensionL×B×Hmm

2885×1290×1420

Net weightkg

2000

gas consumption for 1 hour

7-8 cm3

 

Model of gen-set

40GF-T

rated power(kW)

40

rated voltageV

400

rated power factorCOSΦ

0.8lag

frequencyHz

50

start-up method

DC 24V

voltage regulation

automatic

exciting method

brushless

connecting method

3 phase-4 wire connection

rated speed  (r/min)

1500

lube oil consumption ratio

1.5g/kWh

overall dimensionL×B×Hmm

2040×700×1350

net weightkg

1250

 

model of gen-set

60GF-T

rated power(kW)

60

rated voltageV

400

rated power factorCOSΦ

0.8lag

frequencyHz

50

start-up method

DC 24V

voltage regulation

automatic

exciting method

brushless

connecting method

3 phase-4 wire connection

rated speed  (r/min)

1500

lube oil consumption ratio

1.5g/kWh

overall dimensionL×B×Hmm

2600×850×1650

net weightkg

1750

 

model of gen-set

120GF-RT

engine model

T4190

generator model

1FC

control panel model

PLT-120

rated power (kW)

120

rated currentA

216

rated voltageV

400

rated power factorCOSΦ

0.8lag

frequencyHz

50

start-up method

DC 24V

voltage regulation

automatic

speed governing method

electronic

stabilizing adjustment ratio of speed(%)

5

exciting method

brushless

connecting method

3 phase-4 wire connection

Cooling method for Circulation Water

closedwater tank with fan

coupling method

elastic coupling

cylinder bore (mm)

190

piston stroke (mm)

210

compression ratio

9:01

rated speed (r/min)

1000

idle speed(r/min)

700

lube oil consumption ratio

1.5g/kWh

gas consumption ratiom3/kWh

26full load

heat consumption ratio

11MJ/kWh

vibration

11mm/s

total displacement

Euro

noise

100db(A)

overall dimensionL×B×Hmm

3940×1600×1925

net weightkg

5100

gas consumption for 1 hour

40 nm3

 

model of gen-set

180GF-RT

engine model

6190T

engine type

straight-6 engine, four strokes, with inner cooler, spark-plug ignition

generator model

1FC6

control panel model

PLT-180

rated power (kW)

180

power for long-term running (kW)

160

rated currentA

325

rated voltageV

400

rated power factorCOSΦ

0.8lag

frequencyHz

50

cooling method

forced water cooling

lubricant method

force feed and splash lubrication

start-up method

DC 24V

operating method

manual

voltage regulation

automatic

speed governing method

hydraulic speed regulation

exciting method

brushless

connecting method

3 phase-4 wire connection

coupling method

elastic coupling

cylinder bore (mm)

190

piston stroke (mm)

210

compression ratio

9:01

total displacement(L)

35.73

rated speed (r/min)

1000

idle speed (r/min)

700

gas consumption ratio (m3/kWh)

51(full load)

heat consumption ratio (kJ/kWh)

10500

lube oil consumption ratio   (g/kWh)

1.5

vibration

0.8mm/s

noise

90 db

gas consumption for 1 hour

60 nm3

overall dimensionL×B×Hmm

5325×1725×2207

net-weightkg

8700

model of gen-set

260GF-RT

engine model

T6190ZL-2

generator model

1FC6

control panel model

PLT-260

rated power (kW)

260

rated currentA

470

rated voltageV

400

rated speedr/min

1000

rated power factorCOSΦ

0.8lag

frequencyHz

50

start-up method

DC 24V

voltage regulation method

automatic

speed governing method

electronic speed governor

exhaust temp.(℃)

550

exciting method

brushless

connecting method

3 phase-4 wire connection

coupling method

elastic coupling

overall dimensionL×B×Hmm

4650×2150×2170

net weightkg

8000

gas consumption ratio for 1 hour

87 nm3

 

model of gen-set

400GF-RT

engine model

T12V190

generator model

IFC6

control panel model

PLT-400

rated power (kW)

400

rated currentA

722

rated voltageV

400

rated speedr/min

1000

rated power factorCOSΦ

0.8lag

frequencyHz

50

start-up method

DC 24V

voltage regulation method

automatic

speed governing method

electronic speed governor

exciting method

brushless

phase and connecting method

3 phase-4 wire connection

coupling method

elastic coupling

overall dimensionL×B×Hmm

5925×1970×2638

net weightkg

13500kg

gas consumption ratio for 1 hour

133 nm3

 

model of gen-set

500GF-T

engine model

T12V190ZLD

generator model

1FC6

control panel model

PLT-500

rated speedr/min

1000r/min

rated power (kW)

500kW

rated currentA

902A

rated voltageV

400V

rated power factorCOSΦ

0.8lag

frequencyHz

50Hz

phase and connecting method

3 phase-4 wire connection

voltage regulation method

automatic

exciting method

brushless

speed modulating model

2301A  modulator

start-up method

DC 24V

cooling method

forced water cooling, heat exchanger

over-all dimensionmml×b×h

5925×1970×4680

net weight

13500kg

gas consumption for 1 hour

167 nm3

 

Model of Generator set

600GF1-RT

Engine Model

TP12V190ZL-2A

Generator Type

1FC6 456-6LA42-Z

Control Panel Type

PCK1-500D

Rated Power          (kW)

600

Rated Current        A

1025

Rated Voltage        V

400

Rated Power Factor   COSΦ

0.8Lag

Rated Frequency     Hz

50

Starting Mode

24 V DC Motor or pneumatic motor

Controlling Mode

Manual

Voltage Regulating Mode

Automatic

Governing Method

Electronic Governing

Excitement

Brushless

Wiring Method

Three phase, four Wiring

Cooling by Circulating Water

With radiator2127×2000×2540

Connecting Method

Flexible coupling

Dimensions       l×b×hmm

5506×1970×2698

Weight of Generator set kg

12600

 

model of gen-set

1000GF-RT

 

engine model

16V165ZLDK

 

generator model

1FC6506-4

 

control panel model

PLT1200A.00

 

rated power (kW)

1000

 

rated currentA

1804

 

rated voltageV

400

 

rated power factorCOSΦ

0.8lag

 

frequencyHz

50

 

start-up method

DC 24V

 

voltage regulation method

automatic

 

speed governing method

electronic speed governor

 

exciting method

brushless

 

phase and connecting method

3 phase-4 wire connection

 

cooling method

forced water cooling, heat exchanger

 
 

coupling method

elastic coupling

 

over-all dimensionmml×b×h

5100×1618×2100

 

net weight

13600 kg




Inquire now